Search...
English

Guide to Domestic Substitution of Imported Normal-Phase Columns

Many laboratories typically use C18 reversed-phase columns most of the time. When encountering samples such as fat-soluble intermediates, steroids, sugar alcohols, saponins, and alkaloids — which have very weak retention on reversed-phase columns — normal-phase liquid chromatography is required. Many peers have reported that normal-phase columns are more "delicate" than reversed-phase columns: retention drifts, peaks tail, and columns quickly fail if not handled carefully. Coupled with long delivery times and large price fluctuations for imported columns, everyone is looking for stable and reliable domestic alternatives.

As a domestic manufacturer deeply engaged in LC packings for many years, Elite has a comprehensive normal-phase column product line, ranging from classic older models and high-stability upgraded models to core-shell columns suitable for rapid testing. It covers conventional normal-phase applications while also accommodating HILIC (Hydrophilic Interaction Liquid Chromatography) separation scenarios, adapting to routine testing and method development in pharmaceutical companies, third-party testing, flavors and fragrances, grain and oil, and chemical R&D laboratories.

I. Full Series of Elite Normal-Phase Columns

Relying on independent silica synthesis, surface bonding, and packing technologies, Elite normal-phase columns are divided into 5 major product lines, covering conventional analysis, high-stability BDS, high-performance Supersil, rapid core-shell, and classic SinoChrom:

Elite Normal-Phase Column Full Series Selection Reference Table

Series Classification

Column Model

Stationary Phase

Core Features

Recommended Suitable Samples

Hypersil Packing Analytical Columns

Hypersil SiO₂

Unbonded silica

Classic normal-phase silica, high cost-effectiveness, stable batches

Fat-soluble pharmaceutical intermediates, steroids, oils, hydrocarbons, flavors and fragrances

Hypersil CN

Cyano

Medium polarity, can be used for both normal-phase / reversed-phase, controllable tailing

Polar additives, fat-soluble vitamins, pesticide residues

Hypersil NH₂

Amino

Classic amino stationary phase, suitable for sugar separation

Monosaccharides, oligosaccharides, sugar alcohols, polar lipids

Hypersil BDS Analytical Columns

Hypersil BDS CN

BDS deactivated cyano

Alkaline deactivated silica, reduces silanol adsorption, improves tailing of basic samples

Alkaloids, basic polar intermediates, fat-soluble amines

Supersil Packing Analytical Columns

Supersil SiO₂

Ultra-pure spherical silica

Ultra-high purity silica, higher column efficiency, smaller batch-to-batch variation

Benchmarking imported silica columns, pharmacopoeia method transfer, high-requirement samples

Supersil CN

Cyano

High bonding density, stability superior to older Hypersil CN

Complex polar mixtures, method development, replacement of imported cyano columns

Supersil NH₂

Amino

High-stability amino phase

Sugars, polysaccharide derivatives, glycerides

Supersil NH₂ Plus

Modified amino

Improved hydrolysis resistance, suppresses secondary adsorption

Easily tailing basic sugar amines, amino alcohol samples

Supersil Diol

Diol

Moderate polarity, hydrolysis stability superior to amino columns, can use HILIC mode

Saponins, nucleosides, polar natural products

Supersil Amide

Amide

Hydrolysis resistant, preferred for HILIC mode, not easily lost

Strongly polar water-soluble samples, sugar alcohols, organic acids, polar drugs

Supersil HILIC

HILIC stationary phase

Hydrophilic retention, suitable for strongly polar substances

Strongly polar small molecules, metabolites, additives

Supersil HILIC-ARG

Arginine-modified HILIC

Special selectivity, unique separation of polar ionic compounds

Polar ionic intermediates, amino acid derivatives

Core-Shell Columns

Supersil Coreshell CN

Core-shell cyano

Core-shell structure, fast mass transfer, low column pressure, fast analysis

High-throughput screening, rapid testing of large batches of samples

Supersil Coreshell Bio CN

Bio-specific core-shell cyano

Low non-specific adsorption, suitable for biological fat-soluble samples

Lipids, biological extracted fat-soluble components, biological sample screening

SinoChrom Packing Analytical Columns

SinoChrom SiO₂

Silica

Si60 pore size, traditional classic packing, adapts to old national/industry standards

Follow-up of old standards, replication of old methods, routine oil testing

SinoChrom Si60

60Å silica

Fixed pore size silica, suitable for medium molecular weight fat-soluble components

Oils, hydrocarbon mixtures, fat-soluble extracts

II. Why Many Laboratories Choose Elite for Normal-Phase Work

First, the entire process is independently produced. Silica synthesis, bonding modification, packing classification, column packing, and factory testing are all completed in our own factory, without relying on overseas supply chains. There are no issues with stockouts or long delivery cycles. Routine models are basically in stock, and urgent orders can be coordinated.

Second, comprehensive stationary phase coverage makes substitution of imported columns convenient. Silica, cyano, amino, diol, amide, special HILIC, and core-shell rapid separation columns are all available. Whether it is a traditional normal-phase method with a hexane system or a HILIC hydrophilic method with a high organic phase, a matching column can basically be found without major method modification, reducing the workload of method transfer.

Third, controllable batch stability meets compliance requirements. The highly recommended Supersil series uses high-purity spherical silica. Every batch of packing and packed columns undergoes column efficiency and retention verification, with strict control of retention time RSD. It is suitable for scenarios with high data reproducibility requirements, such as pharmaceutical GMP and CMA third-party laboratories.

Fourth, the product line gradient is clear, allowing selection on demand. For limited budgets and routine quality control, Hypersil and SinoChrom are sufficient. For pharmacopoeia and high-requirement development, prioritize Supersil. For large sample volumes and rapid screening, directly choose the Coreshell series — you don't need to pay extra for performance you won't use.

Fifth, practical supporting technical support. Our technical engineers are familiar with common issues in normal-phase and HILIC systems. Whether you are unsure about selection, how to adjust the mobile phase, or the column has a fault, you can communicate with us. At the same time, we can provide corresponding quality inspection reports and validation documents to facilitate method validation archiving in the laboratory.

Sixth, optimized for industry pain points. BDS deactivated matrix, NH₂ Plus modification, and Amide hydrolysis-resistant formula are specifically designed to solve common troubles such as easy hydrolysis of amino columns, tailing of basic samples, and HILIC phase loss. They extend column service life, saving considerable consumable costs over the long term.

III. Daily Use of Normal-Phase Columns

The biggest enemy of normal-phase columns is water. Many cases of retention drift and poor resolution have their root cause in moisture control.

Frequently Asked Questions (FAQ)

Q1: The retention of the silica normal-phase column is getting earlier and earlier, with peaks eluting ahead of time. What is the cause?
A: The most common cause is moisture absorption by the mobile phase, increasing the water content in the system. The second is contamination of the column by adsorption of strongly polar impurities. First check whether the solvent is sealed and dry, and equilibrate with dry n-hexane-isopropanol for an extended period. For mild contamination, slowly increase the isopropanol ratio for flushing; columns with severe contamination are basically difficult to restore.

Q2: When using an amino column for basic samples, the peaks tail severely. How to improve?
A: Basic substances easily undergo secondary adsorption with residual silanol groups on the silica. Prioritize switching to deactivated matrices such as Supersil NH₂ Plus or Hypersil BDS CN. At the same time, strictly control the water content of the system, as water amplifies the tailing problem.

Q3: What is the difference between HILIC and traditional normal-phase? How to choose between a diol column and an amide column?
A: Traditional normal-phase is mainly based on non-polar solvents such as n-hexane; HILIC uses a high organic phase with a small amount of water to retain strongly polar, water-soluble samples such as sugar alcohols, nucleosides, and polar drugs. The Diol column has balanced stability; the Amide column has better hydrolysis resistance and is suitable for long-term stable HILIC methods.

Q4: What is the difference between core-shell CN and ordinary fully porous CN?
A: Core-shell columns have lower column pressure and faster analysis speed, suitable for high-throughput short methods; fully porous packings have higher loading capacity, suitable for high-concentration samples, pharmacopoeia constant-level testing, and pre-preparative separation.

If you have samples and don't know whether to choose a silica column, cyano column, amino column, or HILIC amide column, or if you want to find a replacement model for a corresponding imported column, you can directly send your sample information and existing testing method to our technical team. We will help you evaluate the appropriate column type, and you can also apply for a test evaluation.

Share to:
Contact us
×
* Required field
Thanks
Your info had been submitted.
Site Search
Find products, applications, and technical resources