English

SinoPak C18

SinoPak Series SinoPak chromatographic packing utilizes a novel ultra-pure silica matrix characterized by narrow particle size distribution and low metal impurity content. Its most popular C18 bonded phase is distinguished by an exceptionally high surface bonding density, making it an ideal choice for the separation of various organic compounds. Suitable for isolating most neutral, acidic, and alkaline compounds as well as chelated samples, SinoPak C18 can also be bonded with multiple functional groups including C8 and Phenyl phases, offering versatile solutions to meet diverse separation requirements.

  • Perfectly spherical silica gel with narrow particle size distribution
  • Excellent chromatographic peak shape
  • Superior selectivity and separation capability
  • Outstanding batch-to-batch reproducibility
  • Exceptional mechanical strength and extended column lifetime
  • Excellent resistance to acidic and alkaline conditions
SinoPak C18
SinoPak C18
SinoPak Packing Parameters
Stationary PhaseParticle Size (μm)Specific Surface Area (m2/g)Pore Size (Å)Carbon Content (C%)End-capping
SinoPak C183/530012021Y

Application



1.Thiabendazole 2.O-phenylphenol 3.Diphenyl

Thiabendazole,O-phenylphenol and Diphenyl Analysis

  • Column: SinoPak C18, 5 μm, 4.6 mm × 250 mm
  • Mobile phase: Precisely weigh 0.681g of sodium dodecyl sulfonate, add 350 mL of methanol, 50 mL of acetonitrile, 100 mL of water and 1 mL of phosphoric acid, mix well, filter and then use.
  • Flow rate: 0.5mL/min
  • Detection: 247 nm
  • Injection volume: 20 μL
  • Column temperature: 40 °C

Aspartame, benzoic acid, sorbic acid, saccharin sodium Analysis

  • Column: SinoPak C18, 5 μm, 4.6 mm × 250 mm
  • Mobile phase: Methanol: 0.02 mol/L ammonium acetate = 10 : 90
  • Flow rate: 1.0 mL/min
  • Detection: 230 nm
  • Injection volume: 10 μL
  • Column temperature: 30°C

How It Works

The new silicone ultra-pure matrix, bonded with octadecylsilane, has better mechanical strength, narrow particle size distribution, excellent batch reproducibility and long lifespan. It has a larger surface bonding coverage and carbon loading, making it an ideal choice for the separation of organic compounds. It is suitable for analyzing complex samples of traditional Chinese medicine.



 Hydrogen Bonding Capacity Test Chromatogram

Effective End-capping

  • Chromatographic column: SinoPak C18 5μm, 4.6×150 mm
  • Mobile phase: Methanol / Water = 30 / 70
  • Flow rate: 1.0 mL/min
  • Wavelength: 254 nm
  • Column temperature: 30°C
  • Test compounds: 1. Uracil, 2. Caffeine, 3. Phenol
 Test ItemEvaluation MetricDetection ResultConclusionReference Criteria
Hydrogen bonding capacityα caffeine/phenol0.37Low binding capacity≤0.6,Low binding capacity>0.6,High binding capacity
  • Chromatographic column: SinoPak C18 5μm, 4.6×150 mm
  • Mobile phase: Methanol : 20 mmol/L phosphate buffer (pH 2.7) = 30 : 70
  • Flow rate: 1.0 mL/min
  • Wavelength: 254 nm
  • Column temperature: 30°C
  • Test compounds: 1. Uracil, 2. Aniline, 3. Phenol
 
 Test ItemEvaluation MetricDetection ResultConclusionReference Criteria
Ion exchange sitesα aniline/phenol0.06Relatively few exchange sites≤0.2,Relatively few exchange sites0.2-0.4,Moderate exchange sites>0.4, Many exchange sites

Excellent Hydrophobic Selectivity and Stereoselectivity

  • Chromatographic column: SinoPak C18 5μm, 4.6×150 mm
  • Mobile phase: Methanol : Water = 80 : 20
  • Flow rate: 1.0 mL/min
  • Wavelength: 254 nm
  • Column temperature: 30°C
  • Test compounds: 1. Uracil, 2. Butylbenzene, 3. Terphenyl, 4. Pentylbenzene, 5. Triphenylene
 
 Test ItemEvaluation MetricDetection ResultConclusionReference Criteria
Hydrophobic Selectivityα Pentylbenzene/Butylbenzene1.49High Selectivity≤1.3,Low Selectivity1.3-1.45,Medium Selectivity>1.45,High Selectivity
Stereoselectivityα Triphenylene/o-Terphenyl1.69High Selectivity≤1.3,Low Selectivity1.3-1.45,Medium Selectivity>1.45,High Selectivity

Excellent Batch Repeatability

Ordering Information

Stationary PhaseParticle Size (μm)Size (mm)P/N
SinoPak C1834.6×5031111208-C
34.6×10031111209-C
34.6×15031111210-C
54.6×15031110107-C
54.6×20031110108-C
54.6×25031110109-C

*For column specifications not mentioned, please contact us for further information.