English

SinoPak BEH T-C18

SinoPak®BEH Series This hybrid silica packing combines the advantages of both organic and inorganic materials, delivering the high column efficiency, high mechanical strength, and stable retention characteristics of pure silica, alongside the broad pH stability and reduced acidic silanol activity of polymer-based packings. Even under extreme conditions, it maintains excellent column longevity.

The hybrid silica packing reduces surface silanol effects:

  • Bonding via triazole linkage significantly minimizes phase loss.
  • Excellent acid and alkali resistance (pH 1.0-12.5), ensuring strong column durability even under harsh conditions.
  • Dual end-capping technology thoroughly eliminates residual silanols.
  • Provides superior selectivity and excellent batch-to-batch reproducibility.
SinoPak BEH T-C18
  • Octadecylsilane bonded ethylene bridge hybrid silica gel, with excellent stability and long service life.
  • Trichloroalkyl bonded, basic double-ended tailing technology, with good peak shape for basic compounds.
  • Tolerant to a wide pH range and high column temperature conditions, widely applicable.
  • Transformation from microanalysis to preparative methods.
  • Method development for unknown multi-component samples.
SinoPak®BEH Packing Parameters
Stationary Phase Particle Size (μm) Specific Surface Area (m2/g) Pore Size (Å) Carbon Content (C%) End-capping
SinoPak BEH T-C18 1.8/2.5/3/5/10 180 130 18 Y
SinoPak BEH T-C18

Application



1.Aflatoxin G2; 2. Aflatoxin G1; 3. Aflatoxin B2; 4.Aflatoxin B1

Aflatoxin Analysis

  • Column: SinoPak BEH T-C18, 5 μm, 4.6 mm × 250 mm
  • Mobile phase: Methanol/Acetonitrile/Water = 29/17/54 (v/v/v)
  • Flow rate: 1.2 mL/min
  • Detection: Excitation wavelength: 333 nm, Emission wavelength: 460 nm
  • Injection volume: 10 μL
  • Column temperature: 40 °C

How It Works

Octadecylsilane bonded ethylene bridge hybrid silica gel, with excellent stability and long service life. Trichloroalkyl bonded, basic double-ended tailing technology, with good peak shape for basic compounds. The multiple bonded phase design can increase the selectivity of method development and reduce the difficulty of development.

Excellent Batch Reproducibility

The hybrid silica particles exhibit uniform particle size and exceptional batch-to-batch consistency and reproducibility.

Extremely High Acid-Base Tolerance
Continuous flushing for 10 days under high temperature using mobile phases at pH = 1.0 and pH = 12.5.



Column Acid-Base Resistance Lifetime Test Results

The long-term acid-base resistance test results demonstrate excellent stability under both low and high pH conditions, with consistent chromatographic performance maintained throughout; outstanding column longevity is achieved.

Ordering Information

Stationary Phase         Particle Size (μm) Size (mm) P/N
SinoPak BEH T-C18 10 4.6×50 3111-36166-031-C
10 4.6×100 3111-36166-041-C
10 4.6×150 3111-36166-041-C
10 4.6×200 3111-36166-061-C
10 4.6×250 3111-36166-071-C
5 2.1×30 3111-36156-221-C
5 2.1×50 3111-36156-231-C
5 2.1×100 3111-36156-241-C
5 2.1×150 3111-36156-251-C
5 4.0×100 3111-36156-441-C
5 4.0×150 3111-36156-451-C
5 4.0×200 3111-36156-461-C
5 4.0×250 3111-36156-471-C
5 4.0×300 3111-36156-481-C
5 4.6×50 31111378-C
5 4.6×100 31111379-C
5 4.6×150 31111380-C
5 4.6×200 3111-36156-061-C
5 4.6×250 31111381-C
5 4.6×300 3111-36156-081-C
3 2.1×30 31111386-C
3 2.1×50 31111387-C
3 2.1×100 31111388-C
3 2.1×150 31111389-C
3 4.0×30 3111-36136-421-C
3 4.0×50 3111-36136-431-C
3 4.0×100 3111-36136-441-C
3 4.0×150 3111-36136-451-C
3 4.6×30 3111-36136-021-C
3 4.6×50 31111382-C
3 4.6×100 31111383-C
3 4.6×150 31111384-C
3 4.6×200 3111-36136-061-C
3 4.6×250 31111385-C
2.5 2.1×30 3111-361256-221-C
2.5 2.1×50 3111-361256-231-C
2.5 2.1×100 3111-361256-241-C
2.5 2.1×150 3111-361256-251-C
2.5 4.6×30 3111-361256-021-C
2.5 4.6×50 3111-361256-031-C
2.5 4.6×100 3111-361256-041-C
2.5 4.6×150 3111-361256-051-C
1.8 2.1×30 3111-36126-221-C
1.8 2.1×50 3111-36126-231-C
1.8 2.1×100 3111-36126-241-C
1.8 2.1×150 3111-36126-251-C
1.8 4.6×30 3111-36126-021-C
1.8 4.6×50 3111-36126-031-C
1.8 4.6×100 3111-36126-041-C
1.8 4.6×150 3111-36126-051-C

* If you need guard or prep-columns, for column specifications not mentioned, please contact us for further information.

For guard columns, SPE columns, and laboratory general consumables, please feel free to contact us.

Contact Us

Thanks
Your info had been submitted.
Contact us
×
* Required field
Thanks