The Amber series represents Elite's latest size exclusion chromatography columns, including the Amber SEC series for aqueous phases and the Amber GPC series for organic phases.

Amber SEC columns are produced using patented surface modification technology, which involves bonding a uniform, nanoscale-thick neutral hydrophilic film onto a high-purity silica gel matrix with excellent mechanical stability. The process employs controlled chemical modification technology, ensuring complete coverage of the hydrophilic coating and reliable column-to-column reproducibility. This series of columns not only exhibits exceptional stability but also demonstrates minimal nonspecific adsorption for biological samples such as proteins. The carefully designed large pore volume ensures high separation capacity and excellent resolution, making it widely applicable for the separation and detection of biomolecules and water-soluble polymers.
| Name | Particle Size (μm) | Pore Size (Å) | Molecular Weight Exclusion Range | Molecular weight range of water-soluble polymers | pH Range | Salt concentration range |
|---|---|---|---|---|---|---|
| Amber SEC 80 | 3 | 80 | 100 ‒ 50,000 | 500 ‒ 5,000 | 2 ‒ 8.5 | 20 mM - 2.0 M |
| Amber SEC 100 | 3 | 100 | 100 - 100,000 | 500-10,000 | 2 ‒ 8.5 | 20 mM - 2.0 M |
| Amber SEC 150 | 3 | 150 | 500 - 150,000 | 500-25,000 | 2 ‒ 8.5 | 20 mM - 2.0 M |
| Amber SEC 300 | 3 | 300 | 5,000 ‒ 1,250,000 | 1,000-100,000 | 2 ‒ 8.5 | 20 mM - 2.0 M |




Sample: BSA control (5mg/mL in Sodium acetate),10 μLPEG 20 kD,10 mg/mL,5μ L20 kD Pegylated BSA,4.23 mg/mL,12μL
The Amber SEC size exclusion chromatography column uses 3 μm monodisperse spherical silica gel as the packing material, with a nanoscale neutral hydrophilic film covalently bonded to its surface. Surface bonding technology ensures maximum surface functionalization of the packing, endowing it with high chemical stability and extremely low non-specific adsorption.
This column is suitable for the separation and preparation of conventional biological samples, including proteins, nucleic acids, oligonucleotides, polypeptides and viruses. It is also applicable for the analysis and purification of neutral polymers, including polysaccharides, synthetic polymers and nanomaterials.
Protein molecular weight calibration curve for Amber SEC

| P/N | Name | Size | Molecular Weight Exclusion Range | Applicable Solvents |
|---|---|---|---|---|
| 3111-80b32-g81-C | Amber SEC80 3μm | ID7.8*300mm | 500 ‒ 5,000(water-soluble polymers) 100-50,000(proteins) | Conventional Aqueous and Organic Solvents |
| 3111-80b34-g81-C | Amber SEC100 3μm | ID7.8*300mm | 500-10,000(water-soluble polymers) 100-100,000(proteins) | |
| 3111-80b3a-g81-C | Amber SEC150 3μm | ID7.8*300mm | 500-25,000(water-soluble polymers) 500-150,000(proteins) | |
| 3111-80b39-g81-C | Amber SEC300 3μm | ID7.8*300mm | 1,000-100,000(water-soluble polymers) 5,000-1,250,000(proteins) |