English

Amber GPC 100/300/500/1000/MP 5µm

The Amber series represents ELITEHPLC's latest size exclusion chromatography columns, including the Amber SEC series for aqueous phases and the Amber GPC series for organic phases.

Amber GPC 100/300/500/1000/MP 5µm
Amber GPC

Amber GPC columns are specifically designed for high-efficiency separation of synthetic polymers. Based on highly cross-linked polystyrene/divinylbenzene (PS/DVB) particles with extremely narrow particle and pore size distributions, it delivers uniform pore size distribution that ensures accurate linear correlation between retention time and molecular weight. The highly cross-linked porous particles exhibit exceptional chemical and physical stability, maintaining consistent molecular weight calibration curves and column efficiency even when switching organic solvents. With large pore volume, Amber GPC packing guarantees high resolution in polymer separations. The packing is available as either single-pore-size resin or blended resins with different pore sizes.

Specification
Stationary Phase  Particle Size (μm) Pore Size (Å) MW exclusion range pH Range Maximum Pressure(psi)
Amber GPC 100 5 100 100 - 100,000 1-14 5000
Amber GPC 300 5 300 500-250,000 1-14 5000
Amber GPC 500 5 500 1,000-750,000 1-14 5000
Amber GPC 1000 5 1000 5,000-2,500,000 1-14 5000
Amber GPC-MP 5 100-1000 5,000-2,500,000 1-14 5000

Application

Polystyrene

  • Column: Amber GPC 500 ( 5 µm, 500 Å, 7.8 x 300 mm )
  • Mobile phase: DMF + 0.25 % TBAB
  • Flow rate: 0.8 mL/min
  • Detection: Refractive index ( 35℃ )
  • Injection volume: 20 µL
  • Column temperature: Room temperature
  • Sample: 10.0 mg/mL polystyrene ( 70 kD )

Cefterampivoxil

  • Column: Amber GPC 100 ( 5 µm, 100 Å, 7.8 x 300 mm )
  • Mobile phase: DMF + 20 mM LiBr
  • Flow rate: 0.5mL/min
  • Detection: UV263nm
  • Injection volume: 20 µL
  • Sample: 1 mg/mL Cefterampivoxil

1.Triglyceride Diacylglycerol 3. Monoglyceride

Glyceride in fish oil

  • Column: Amber GPC 300, 5 µm, 300 Å, 7.8 × 300 mm
  • Amber GPC 100, 5 µm, 100 Å, 7.8 × 300 mm
  • Mobile phase: THF
  • Flow rate: 1.0mL/min
  • Detection: Refractive index
  • Column temperature: Room temperature

How It Works

  • Matrix: Highly cross-linked polystyrene/divinylbenzene (PS/DVB) particles
  • Compatibility: Applicable to virtually all organic solvents (e.g., THF, DMAC, DMF, TCB, NMP, HFIP)
  • Max Temperature Resistance: 145°C
  • Uniform particle and pore size distribution
  • High pore volume and resolution
  • Low background noise in light scattering detection

In routine polymer analysis, the molecular weight of samples can reach 2,000,000 Daltons, and analytical and preparative separations can be performed under elevated temperature conditions.

Typical applications include: Polystyrene, polyolefin, polyacrylate, polysiloxane, polycarbonate, resins.

Polystyrene molecular weight calibration curve

Polystyrene molecular weight: 570Da,1920Da,3460Da,9580Da,17300Da,27500Da,62300Da,

139000Da,319000Da,601800Da,1103000Da,1760000Da,2860000Da

Ordering Information

P/N Name Size (mm) Molecular Weight Exclusion Range Applicable Solvents
3111-80a54-g81-C Amber GPC100 5μm ID7.8*300mm 100 - 100,000 Almost all organic solvents(Such as  THF, DMAC, DMF, TCB, NMP, HFIP, etc.)
3111-80a59-g81-C Amber GPC300 5μm ID7.8*300mm 500-250,000
3111-80a5b-g81-C Amber GPC500 5μm ID7.8*300mm 1,000-750,000
3111-80a5d-g81-C Amber GPC1000 5μm ID7.8*300mm 5,000-2,500,000
3111-80a5h-g81-C Amber GPC-MP 5μm ID7.8*300mm 5,000-2,500,000
For guard columns, SPE columns, and laboratory general consumables, please feel free to contact us.